Perkins 1500 KVA Generator Specification

Perkins 1500 KVA Generator Specification
Perkins 1500 KVA Generator Specification

Are you searching for large Perkins generator1500 KVA rating, here in this blog we are sharing some important and basic Perkins 1500 KVA Generator Specification. Read and choose the best generator – Perkins Generator 1500 KVA for your high and emergency power backup needs.

Benefits of Perkins 1500kVA Generators:

  1. Phenomenal damping execution: improvement and plan of the damping framework dependent on powerful PC reproductions.
  2. Propelled control framework: control procedures of entire observing framework dependent on the unwavering quality structure.
  3. Green ecological assurance: diesel gensets coordinated with vitality sparing and low emanation.
  4. Low Noise: exhaust and quieting framework is redone for each set.
  5. Great execution: stable running, little vibration, low fuel utilization, low oil utilization, long-running life and short upgrade and low noise.

Electrical execution of Perkins generators:

As per the standard GB2820 and ISO8528/3. Adjusting to specialized necessities for the YD/T502 correspondence diesel gensets of the post and broadcast communications framework.

Rated voltage:400/230V

Connection mode: three-stage four-wire

Frequency:50Hz

Rated power factor:0.8 (slack)

Radio obstruction concealment: consent to the arrangements of VDE0875-N Class and GB2820 guidelines

Generator Features-

  • Cooling System – Water Cooling
  • Fuel Type – Diesel
  • Dislodging – 61.123 litres
  • Brand – Perkins
  • Bore And Stroke – 160 x 190 mm
  • Pressure Ratio – 13.61
  • Number of Cylinder – 16
  • Cycle – 4 strokes
  • Burning framework – Direct infusion
  • All out greasing up limit – 237.2 litres
  • All out coolant limit – 215 litres

Perkins Generator 4000 Series

The Perkins 4000 Series group of 6, 8, 12 and 16-chamber diesel motors was planned ahead of time of the present’ inflexible requests inside the force age industry and incorporates unrivalled execution and unwavering quality

Their top-notch structure and particular highlights give financial and tough activity just as uncommon capacity to weight proportion, improved usefulness, low vaporous discharges, in general execution and dependability basic to the force age showcase.

Fuel System of 1500kVA Perkins Generator

Direct fuel infusion framework with fuel lift siphon

Computerized administering to ISO 8528-5 class G2 with isochronous capacity

Full-stream turn on fuel oil channels

Cooling System

Two triple indoor regulators

Powder covered radiator involving water radiator, air charge-cooled radiator, fuel oil cooling (discretionary), all channels, hoses and clasps, fan, pulleys, fan belts and well-being monitors

Oil System

Wet sump with filler and dipstick

Full-stream turn on oil channels

Electrical features

  • 24 volt starter engines and 24 volt alternators with fundamental controller and DC yield
  • Generator bay temperature shutdown switch
  • Twin high coolant calm shutdown switches
  • Twin low oil pressure shutdown switches
  • Air shut off valve wiring bridle – completely wired

Working Function of Perkins generators

After the spotless air sifted by the air cleaner and the high weight atomized diesel infused from the spout are completely blended inside the chamber of the diesel motor, the volume psychologists and temperature rises quickly under the upward expulsion of the cylinder, at that point the start purpose of the diesel is reached. In this way the diesel is lighted, the blended gas is in serious burning, the volume quickly extends and the cylinder is pushed descending, which is known as the “Work Done”.Each chamber accomplishes work in a specific arrangement, and the push on the cylinder transforms into the force advancing the turn of the driving rod in the wake of experiencing interfacing pole, in order to drive the driving rod pivot. At the point when the driving rods of the brushless coordinated air conditioning generator and diesel motor are in co-pivotal establishment, we can utilize the turn of the diesel motor to drive the generator rotor, and utilize the ‘electromagnetic enlistment’ guideline to drive the generator yield acceptance electromotive power, at that point the shut burden circuit will create an electric flow.

Control Panel of Perkins 1500KVA Generators:

There are various sorts of control boxes, for example, manual, programmed, far off observing and programmed savvy types. Essential design incorporates voltmeter, The ammeter, water thermometer, oil pressure check, preheat controller, crisis stop button, button, battery voltmeter, plan, stage selector switch, and so forth.

If you want more information about the best power generator, you can visit our site and contact with EO Energy team. They provide you the best support for buying the best generator.

Keerthana

Keerthana is the best content writer in Technonguide, She writes about Applications, Games, and helpful websites on because she loves new Technology and programs that make life easier.

Leave a Reply

Your email address will not be published. Required fields are marked *